🧮 Laboratory Math Review for the MedTech Board Exam

Significant figures and units, solutions and dilutions, concentration calculations, and the statistics behind quality control. Learn it the fun way: bite-size lessons, instant feedback, spaced repetition, flashcards, quizzes and PvP battles. Free.

Start Laboratory Math free Laboratory Math flashcards

What the Laboratory Math course covers

  1. Unit 1: Numbers & Units

    Significant figures, powers of ten, logs and pH, metric prefixes, English units and temperature.

    Significant figures · Powers of ten, logs & pH · Metric & SI units · English units, temperature & time

  2. Unit 2: Reagents & Solutions

    Reagent water, chemical grades, making percent and molar solutions, normality, pH and concentrated reagents.

    Reagent water & chemical grades · Making percent & molar solutions · Equivalents & normality · pH, buffers & concentrated reagents

  3. Unit 3: Dilutions & Lab Formulas

    Diluting stocks and samples, serial dilutions and titers, unknowns from standards, enzyme rates, unit conversions and clearance.

    Diluting stocks & samples · Serial dilutions & titers · Unknowns from standards · Enzyme rates, conversions & clearance

Sample Laboratory Math board exam questions

A few practice questions from the course, with explanations. Thousands more are in the app.

  1. 1. How many significant figures are in 1.0040?

    1. 3
    2. 4
    3. 5
    4. 2
    Show answer

    Answer: C. 5

    Rules: nonzero digits count; zeros between them count; trailing zeros after a decimal point count; leading zeros never count. In 1.0040: 1, 0, 0, 4 and the final 0 all count = 5 significant figures.

  2. 2. Which purification step mainly removes dissolved organic compounds and chlorine?

    1. 0.2 µm filtration
    2. Deionization
    3. Activated carbon
    4. Ion-exchange softening
    Show answer

    Answer: C. Activated carbon

    Activated carbon adsorbs dissolved organic compounds and chlorine. Deionization (ion exchange) removes charged ions only; a 0.2 µm filter removes bacteria and particles.

  3. 3. 50 µL of serum is mixed with 450 µL of diluent. The dilution is:

    1. 1:5
    2. 1:10
    3. 1:9
    4. 1:450
    Show answer

    Answer: B. 1:10

    Dilution = sample volume ÷ total volume = 50 ÷ (50 + 450) = 50 ÷ 500 = 1/10, a 1:10 dilution. It is not 1:9: count the total, not just the diluent.

  4. 4. 4.56 × 1.4 = ? (correct significant figures)

    1. 6
    2. 6.38
    3. 6.384
    4. 6.4
    Show answer

    Answer: D. 6.4

    In multiplication and division, the answer keeps as many significant figures as the least precise number. 1.4 has 2, so 4.56 × 1.4 = 6.384 is rounded to 2 figures: 6.4.

  5. 5. The resistivity meter on the lab’s water system falls from 15 to 2 MΩ·cm. The most likely cause is:

    1. Too few bacteria
    2. Exhausted deionizer resin letting ions through
    3. A cold room
    4. Water that is too pure
    Show answer

    Answer: B. Exhausted deionizer resin letting ions through

    Resistivity measures how strongly water resists current; ions lower it. Type I water is about 10–18 MΩ·cm. A drop to 2 MΩ·cm means the deionizer resin is exhausted and ions are passing through.

  6. 6. To make 2 mL of a 1:20 dilution, combine:

    1. 0.1 mL sample + 2.0 mL diluent
    2. 1 mL sample + 20 mL diluent
    3. 0.1 mL sample + 1.9 mL diluent
    4. 0.2 mL sample + 1.8 mL diluent
    Show answer

    Answer: C. 0.1 mL sample + 1.9 mL diluent

    Sample volume = total ÷ dilution = 2 mL ÷ 20 = 0.1 mL. Diluent = 2.0 − 0.1 = 1.9 mL. Adding 2.0 mL diluent would make a 1:21.

  7. 7. 25.0 − 1.234 = ? (correct significant figures)

    1. 23.766
    2. 23.8
    3. 23.77
    4. 24
    Show answer

    Answer: B. 23.8

    In addition and subtraction, keep as many decimal places as the number with the fewest. 25.0 has one decimal place, so 25.0 − 1.234 = 23.766 rounds to 23.8.

  8. 8. The final step that removes bacteria and particles from reagent water is usually:

    1. Storage in glass
    2. A 0.2 µm membrane filter
    3. Deionization
    4. Activated carbon
    Show answer

    Answer: B. A 0.2 µm membrane filter

    A 0.2 µm membrane filter at the end of the system traps bacteria and fine particles. Earlier steps (carbon, reverse osmosis, deionization) remove organics and ions.